ABB (TBI) Replacements
This series of Van London Co. pH and ORP sensors are designed to retrofit the TBI/Bailey sensor assemblies. They are manufactured with a unique solid polymer reference gel for extended life in the most severe applications.
|
|
C621 & C621H Stainless Steel Conductivity Probes
The Model C621 & C621 H conductivity electrode provides rugged construction and long term stability through the use of specially treated 316 stainless steel. This probe is engineered to minimize errors due to polarization effects, and respond rapidly to changing temperatures. The C621 series is compatible with most conductivity transmitters that are designed for a standard two electrode cell (not a 4-cell type).
|
|
Conductivity Family
The Van London Co. two electrode conductivity sensors are compatible with most existing analyzers and are available in a variety of mounting and temperature compensator configurations.
|
|
Endress + Hauser® Direct Replacements
This new line of direct replacements for E&H®-style electrodes is now available for a wide variety of pH or ORP applications. They are designed dimensionally to retrofit with existing installations. Expensive equipment changes are no longer necessary.
|
|
Fermprobe® Type Replacements pH/Redox Electrodes
This series of steam sterilizable and autoclavable pH electrodes and ORP electrodes has been designed to retro-fit the Broadley James Corp. FERMPROBE® ELECTRODE HOLDER. These electrodes have been engineered as improved replacements using the same configuration as the original equipment.
|
|
Flow-Through Dissolved Oxygen Assembly
This Dissolved Oxygen system is designed for O2 measurements in a continuous flow-through environment. The cell and O2 electrode are designed to be steam sterilized in the autoclave with the electrode installed. The O2 electrode system is compatible with most common O2 amplifiers.
|
|
Glass Body Dissolved Oxygen Electrodes
The glass body Dissolved Oxygen electrodes are available for laboratory fermentation, where sterilization takes place in a separate autoclave. The disposable Van London Co. Dissolved Oxygen Electrodes are compatible with most common oxygen amplifiers.
|
|
Honeywell (L&N)
Van London Co. Housings can be machined from numerous materials with several electrode guard designs and various insertion depths. Custom electrode designs can maximize sensor in harsh environments.
|
|
ISE: Ammonia
An Ion Selective Electrode sensor specifically designed to measure Ammonia from 0.01 ppm to 17,000 ppm NH3 (5x10-7 M to 1M) concentrations.
Applications include, but not limited to: High Purity Power Station Water, Fish Tanks, Sea Water, Waste Water, Plating Baths, Biological Samples.
|
|
ISE: Ammonium
An Ion Selective Electrode sensor specifically designed to measure 0.1ppm to Saturated (5x10-6M to Saturated) concentrations of NH4.
Applications inclue, but not limited to: Boiler Feed Water, Natural Waters, Fertilizers.
|
|
ISE: Bromide
A Bromide Ion Selective Electrode sensor specifically designed to measure 0.4ppm to Saturated (5x10-6 M to Saturated) concentrations of Bromide.
Applications include, but not limited to: Water, Wine, Soil and Plant Tissue, Blood Electrolytes/Clinical Analysis.
|
|
ISE: Cadmium
A Cadmium Ion Selective Electrode sensor specifically designed to measure 0.01 ppm to 11,200 ppm (10-7 M to 10-1 M) concentrations of Cd+2.
Applications include, but not limited to: Plating Baths.
PRODUCT WARNINGS
WARNING: Cancer & Reproductive Harm - www.P65Warnings.ca.gov
|
|
ISE: Calcium
A Calcium Ion Selective Electrode sensor specifically designed to measure 0.5 ppm to Saturated (5x10-6 M to Saturated) concentrations of Ca+2.
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Blood Elecrtrolytes/Clinical Analysis.
|
|
ISE: Chloride
A Chloride Ion Selective Electrode sensor specifically designed to measure 1.8 ppm to Saturated (5x10-5 M to Saturated) concentrations of Cl-.
Applications include, but not limited to: River and Tap Water, Plant Tissue, Soils, Boiler Feed Water, Blood Electrolytes/Clinical Analysis, Sweat, Urine, Cement, Plating Baths, Food Samples.
|
|
ISE: Copper
A Copper (Cupric) Ion Selective Electrode sensor specifically designed to measure 0.0006 ppm to 6350 ppm (1x10-8 M to 1x10-1 M) concentrations of Cu+2.
Applications include, but not limited to: Plating Baths, Water.
|
|
ISE: Cyanide
A Cyanide Ion Selective Electrode sensor specifically designed to measure 0.13 ppm to 260 ppm (5x10-6 M to 1x10-2 M) concentrations of CN-.
Applications include, but not lmited to: Plating Baths, Waste Water, Plant Tissue.
|
|
ISE: Fluoride
A Fluoride Ion Selective Electrode sensor specifically designed to measure .02 ppm to saturated (1x10-6 M to saturated) concentrations of F-.
Applications include, but not limited to: Drinking Water, Wastewater and Natural Waters, Air and Stack Gases, Acids, Sea Water, Minerals, Soil, Foods, Biological Fluids, Toothpaste.
|
|
ISE: Fluoroborate
A Fluoroborate Ion Selective Electrode sensor specifically designed to measure 0.5 (as B) ppm to 10,800 ppm (7x10-6 M to 1M) concentrations of BF4-.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Iodide
An Iodide Ion Selective Electrode sensor specifically designed to measure 0.006 ppm to Saturated (5x10-8 M to Saturated) concentrations of I-.
Applications include, but not limited to: Milk, Feeds and Plants, Pharmaceuticals.
|
|
ISE: Lead
A Lead Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 20,700 ppm (1x10-6 M to 0.1 M) concentrations of Pb+2.
Applications include, but not limited to: Plating Baths.
PRODUCT WARNINGS
WARNING: Cancer & Reproductive Harm - www.P65Warnings.ca.gov
|
|
ISE: Magnesium
Unique to Van London, the Magnesium Ion Selective Electrode sensor is designed to provide greater accuracy in water hardness, drilling muds, mining, drinking water, mineral water, and sea water. The Mg+2 ISE can also be accurately applied to monitoring total water hardness titrations.
|
|
ISE: Nitrate
A Nitrate Ion Selective Electrode sensor specifically designed to measure 0.5 ppm to Saturated (7x10-6 M to Saturated) concentrations of NO3-.
Applications include, but not limited to: Surface Waters and Sewage Effluent, Drinking Waters and Soil Extracts, Fertilizers, Soils, Plant Tissue, Meat, Potatoes, Spinach, Beets, Baby Food.
|
|
ISE: Nitrogen Oxide
A Nitrogen Oxide Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 220 ppm (5x10-6 M to 5x10-3 M) concentrations of NOx.
Applications include, but not limited to: Air, Stack Gases.
|
|
ISE: Perchlorate
A Perchlorate Ion Selective Electrode sensor specifically designed to measure 0.7 ppm to Saturated (7x10-6 M to Saturated) concentrations of ClO4-.
Applications include, but not limited to: Explosives, Solid Propellants.
|
|
ISE: Potassium
A Potassium Ion Selective Electrode sensor specifically designed to measure 0.04 ppm to Saturated (1x10-6 M to Saturated) concentrations of K+.
Applications include, but not limited to: Waste Water, River and Tap Waters, Blood Electrolytes/Clinical Analysis, Saliva, Serum, Fertilizer, Soils, Wines.
|
|
ISE: Silver
A Silver Ion Selective Electrode sensor specifially designed to measure 0.01 ppm to 107,900 ppm (10-7 M to 1M) concentrations of Silver (Ag+).
Applications include, but not limited to: Plating Baths (Silver), Photographic Fixing Solution (Silver).
|
|
ISE: Sodium
A Sodium Ion Selective Electrode sensor specifically designed to measure 0.02 ppm to Saturated (10-6 M to 5M) concentrations of Sodium (Na+).
Applications include, but not limited to: Steam Condensates in Power Plants, Blood Electrolytes/Clinical Analysis, Serum, Foods, Wine, Sea Water.
|
|
ISE: PPB Sodium
A Sodium Ion Selective Electrode sensor specifically designed to measure 0.1 ppb to 10 ppm concentrations of Sodium (Na+). Application include, but not limited to: Power Plants, Boiler Feed Water.
|
|
ISE: Sulfide
A Sulfide Ion Selective Electrode sensor specifically designed to measure 0.003 ppm to 32,100 ppm (1x10-7 M to 1M) concentrations of Sulfide (S-2).
Applications include, but not limited to: Sewage effluent, Soils, Sediments.
|
|
ISE: Surfactant
A Surfactant Ion Selective Electrode sensor specifically designed to measure 1.0 ppm to 12,000 ppm (10-5 M to 10-2 M) concentrations of surfactants.
Applications include, but not limited to: Detergents, Dishwashing Liquids, Cleaning Supplies, Food Products.
|
|
ISE: Water Hardness
A Water Hardness Ion Selective Electrode sensor specifically designed to measure 0.5 ppm to Saturated (1x10-5 M to Saturated) concentrations of Water Hardness (Calcium and Magnesium).
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Sea Water.
|
|
Laboratory Electrodes
Van London Co. Laboratory electrodes are designed to be used in a variety of applications. These include water quality, soil pH, non-aqueous media, and education. Both glass and plastic body types are available.
|
|
Retractable Lock-N-Load Sensor Assembly
All you need to do is Lock-N-Load to install a pH or ORP electrode into any pipeline. This is the first in-line assembly that doesn't require ball valves, cables, or costly, complex hardware to quickly insert or remove an electrode from a pipeline without interrupting the process.
|
|
Mark 7 Series For pH And ORP Applications (Hot Tap)
The Mark 7 insertion assemblies permit continuous pH or ORP monitoring in pressurized vessels or lines.
Specifications are for mounting onto a weldalet, a pipe tee or flange. To reduce the maintenance
downtime required, electrode connections terminate inside an explosion-proof junction box which houses
the preamp as well.
|
|
Mark X Pneumatic Retractable Sensor Assembly For pH And ORP
The Van London Co. Mark X Pneumatic Retractable pH / ORP Sensor Assembly permits continuous pH or ORP monitoring where service must be performed without process interruption. It can be mounted vertically or inclined in reactors of pilot and production plant facilities.
|
|
Mettler (Ingold®) Direct Replacements
This new line of direct replacements for Mettler Ingold®-style electrodes is now available for a wide variety of pH or ORP applications. They are designed dimensionally to retrofit with existing installations. Expensive equipment changes are no longer necessary.
|
|
Micro Autoclavable Electrodes
This series of miniature steam sterilizable, combination pH and redox electrodes are designed for small bench top fermentors and culture apparatus. The electrodes are designed to fit all 12mm and 6mm electrode holders or rubber stoppers used in bench top fermentors.
|
|
Model P821 Sensor
Specially designed for convenience of electrode replacement where minimal troubleshooting and maintenance downtime are of prime importance. The P821 is suitable for virtually all applications where a high performance sensor is required, either in-line or submersible installation. The electrode features a detachable cable with an integral preamplifier which eliminates any ground loop problems. The preamp converts the high impedance signal into a stable, noise free signal.
|
|
pHastTrac® 2000
The proven design of the pHastTrac® 2000 is ideal for applications in the food, process, pharmaceutical and many other industries where frequent cleaning and calibration of the pH and/or ORP electrode is required. Incorporated in this system is a clean / cal chamber that allows the user to remove the electrode from a process line or tank while maintaining production integrity.
|
|
Refillable pH and ORP Electrodes
This series of steam-sterilizable pH and ORP electrodes are designed for small fermentors where sterilization is performed in an autoclave in non-pressurized operation. The electrodes can withstand repeated sterilization up to 130°C and feature a detachable cable assembly insulated with a water tight connector.
|
|
Rosemount® Replacements
Van London Co. Rosemount® pH replacement sensors have been field proven in a variety of harsh applications. An inventory stocking arrangement reduces lead times from weeks to days. Housed electrodes generally consist of two parts: a 12mm glass-bodied electrode and housing machined to accept that electrode. Minimal factory assembly is required before shipment to the customer site.
|
|
Sealed In-Situ Sensor For Fermentation
This new generation, low cost, steam sterilizable insertion sensor is specifically designed for low maintenance requirements. The assembly is low profile and features an easily replaceable, sealed, combination pH or ORP electrode.
|
|
Sensorex® & Signet® Replacements
The low profile design allows the process flow to clean the pH / ORP sensor tip, and with the addition of the Van London Co. Tuff Tip™ the bulb is protected from physical damage.
|
|
Steam Sterilizable Carbon Dioxide Electrode
The Van London Steam Sterilizable Carbon Dioxide probe is specifically designed for fermentation applications where it is necessary to subject the electrode to repeated steam sterilizations.
|
|
Submersible Sensors For pH, ORP & Conductivity Applications
The Mark I-A and Mark VI-B sensors will continuously monitor pH, ORP, and Conductivity in tanks, vessels, or canals where liquid levels tend to vary. Typical applications include chlorine cells, latex coagulation tanks, and effluent sumps. It can be installed in atmospherically sealed vessels with use of a tank mount fitting.
|
|
SZ 283 Potentiostatic electrode
This sensor is designed for the measurement of Free Chlorine, Chlorine dioxide and Dissolved Ozone in water.
Note: This specific model of potentiostatic chlorine sensor is currently not available to OEM customers, and is only available when ordered as a complete package with the B&C CL 7685 Potentiostatic Cl2 Controller and SZ 7231 - SZ 7233 Flow Cells.
|
|
Threaded pH/ORP Sensors
These inline pH and ORP electrodes are designed for mounting on standard 1” or ¾” pipe tees for continuous pH or ORP flow-through monitoring. They are constructed with a sealed solid polymer reference which requires no pressurization or refilling during use. With the large reference surface area, reference clogging is not a problem.
|
|
Titration Electrodes
The Van London Co. Titrate electrodes are specially designed for all existing Brinkmann, Metrohm and Schott titration systems. The electrode body is constructed with a glass ground joint that will fit their titration vessels.
|
|
Tuff-Fet & Transmitter Non-Glass pH Electrodes
The Tuff-Fet™ sensor is a solid state, ion selective field-effect transistor or ISFET. This technology does not require a glass membrane, making it perfect for Food-Grade Applications.
|
|
Twist-Lock Conductivity Sensors And Adapters
The Twist-Lock sensor, with locking pins and a dual o-ring seal, consists of a 12mm sensor and automatic temperature compensator permanently sealed into the housing. Using the sensor and an adapter, with several different connection sizes available, allows conversion of a standard pipe tee to a flow through sensor assembly.
|
|
Twist-Lock Series For pH Or ORP Applications
The Twist-Lock™ sensor and adapter is designed to convert a standard pipe tee into a low cost, low maintenance flow-through sensor assembly. Only a ¼ turn is required for field maintenance or sensor replacement; threading is eliminated. The adapter is available in a variety of materials & connection sizes for easy installation.
|
|
Weld-In Sockets
25mm and 19mm Weld-In Sockets and accessories.
|
|
Yokogawa® Replacements
Van London Co. Yokogawa pH and ORP electrode replacement designs have been field proven in a variety of harsh applications. In most cases, direct replacements will outperform original equipment specifications.
|