Van London-pHoenix Co. electrodes are manufactured with our Solid Polymer Reference™ fill, the life of the electrode is prolonged and the overall performance of the electrode is enhanced.
|
|
 |
- Improved Life and Performance
Van London-Phoenix Co. electrode designs have been field proven in a variety of harsh applications and when manufactured with our Solid Polymer Reference™ fill the life of the electrode is prolonged and the overall performance of the electrode is enhanced.
- Custom Styles
Housings can be machined from numerous materials with several electrode guard designs and various insertion depths. Custom electrode designs can maximize sensor in harsh environments.
|
- Quick Order Turn-around
An inventory stocking arrangment reduces lead times from weeks to days. Housed electrodes generally consist of two parts: a 12mm glass-bodied electrode and a housing machined to accept that electrode. Minimal factory assembly is required before shipment to the customer site.
- Easy, Low Cost Replacement
Direct replacements are dimensionally matched to existing equipment so that no expensive retrofit changes are necessary. Simple, quick removal of the replacement element for Van London-Phoenix Co. standardization is all that is required.
|
|
| |
| ELECTRODE SELECTION |
| |
| Measurement Types: |
|
GXV - Multi-purpose pH glass formulation (0-14.00 pH)
Platinum Band - For ORP measuremnt (Gold optional)
Antimony - For pH measurements in Hydrofluoric Acid appilcations (2.00-7.00 pH) (0-80°C) |
| |
| Reference Types: |
|
SPR™ - Double junction, SOLID POLYMER REFERENCE (0-130°C)
Tuff-Tip™ - New design incorporating larger reference junction surface area & electrode guard.
LCJ - Dramatically increases the reference junction surface area. Standard material is ceramic, but porous Teflon and porous Kynar are available. |
|
| - |
Call with Great Lakes part numbers for cross-reference to Van London-Phoenix Co. equivalents. |
| - |
To build your own Part Numbers, first determine the electrode replacement, style required, and then replace the X's, Z's & Q's with selections listed in the drop down menu. |
| |
Electrode Selection |
| 461 - |
Z |
X |
|
: Differential pH/5 Wire Sensor/1" MPT Kynar™ housing |
| V-900 - |
Z |
X |
10 H |
: Conventional pH/1" MPT Kynar™ housing |
| |
| |
| |
| |
| |
Measuring Electrode Options |
| |
| |
0 ORP |
| |
| |
V pH |
| |
| |
| ACCESSORIES: |
| |
| 3600105 |
Reducer, Kynar™ 1½" x 1" |
| 9210082 |
Differential Refill Solution |
| 1602100 |
461 Reference Junction |
|
| |
Temperature Compensation (z) |
| |
B PT100 |
| |
1 3K Balco |
| |
7 NTC 300 |
| |
| 458P - |
Z - |
XX - |
QQ |
Preamp Assembly |
| |
| |
| |
| |
| |
| |
| |
Connector Type |
| |
| |
| |
SL Spade Lugs |
| |
| |
| |
H Hanked (Tinned) |
| |
| |
| |
| |
| |
Lead Length |
| |
| |
Specify lead length in even feet |
| |
| |
| |
Preamp Section |
| |
0 No Preamp |
| |
5 (Conventional) |
| |
G (Differential / 5 Wire) |
|
| ELECTRODE SOLUTIONS |
| |
| 9210038 |
4.00pH, 7.00pH and Deionized Water rinse (1 pint each) |
| 9210037 |
4.00pH, 7.00pH and 10.00pH (1 pint each) |
| 9210039 |
7.00pH, 10.00pH and Deionized Water rinse (1 pint each) |
| 9210079 |
Anti-fouling solution to reduce electrode-coating problems |
| 9210008-125 |
Electrode storage solution KCl/4.00 pH buffer (125 ml) |
| |
| Eutech Instruments for pH, ORP, Conductivity, Resistivity & TDS: |
| |
| pH 2000 |
Controller (PI & on/off) |
| pH 800 |
Controller (on/off) |
| pH 200 |
Controller (on/off) |
| pH 500 |
Transmitter |
| |
|
|
|