Mettler (Ingold®) Direct Replacements TEXT SIZE: A A A    PRINT THIS PAGE   EMAIL THIS PAGE

This new line of direct replacements for Mettler Ingold®-style electrodes is now available for a wide variety of pH or ORP applications. They are designed dimensionally to retrofit with existing installations. Expensive equipment changes are no longer necessary.

Tuff-Fet pH Electrode with S8 Fitting 1 Inch MPT Housing pH or ORP Electrode
Tuff-Fet™ pH w/ S8 Fitting 1" MPT Housing pH or ORP
Refillable pH or ORP w/ S7 Cap
Refillable pH or ORP w/ S7 Cap
ealed pH or ORP w/ S8 Cap
Sealed pH or ORP w/ S8 Cap

 

Description
This new line of direct replacements for Mettler Ingold®-style electrodes is now available for a wide variety of pH or ORP applications. They are designed dimensionally to retrofit with existing installations. Expensive equipment changes are no longer necessary. A combination of several reference fills or reference junctions are available to suit specific application requirements. Custom designs are not uncommon.
 
Design Features
The Solid Polymer Reference (SPR™) is Van London Co.'s polymer-based reference comparable to Ingold's® Xerolyt™. Internal "shorting" is more inherent with an open-reference style electrode in pressurized applications. Unlike Ingold®, Van London Co. pairs the SPR™ with a ceramic junction to eliminate possibilities of both electrode shorting and reference poisoning. For additional reliability, the gel is forced into the junction pores during the manufacturing process, virtually eliminating junction clogging by process particulate matter.
 
Specifications
Measurement Types:   GXV - Multi-purpose pH glass formulation (0-14.00 pH)
Reference Types:   SPR™ - Double junction, SOLID POLYMER REFERENCE (0-130°C)
 Tuff-Tip™ - New design incorporating larger reference junction surface area & electrode guard.
 
ORDRING INFORMATION:
 
Sealed pH or ORP w/ S8 Cap Design (glass)
 
  I-100X  -  ZZZ pH electrode
  79 X 6640  -  ZZZ ORP electrode
  * X = Temperature Compensator Option
  * ZZZ = "A" Dimension in millimeters (refer to drawings above). Options are 120, 225, 325, 400 & 425
 
1" MPT Housing (Kynar™)
 
  V-500X  -  YYY pH electrode
  16 X 6083G  -  YYY ORP electrode
  * X = Temperature Compensator Option
  * YYY = Lead length in feet & Connector Option
 
Tuff-Fet™ pH w/ S8 Fitting (Also see Tuff-Fet™ Spec Sheet)
 
  H135  -  ZZZ
  * ZZZ = "A" Dimension in millimeters (refer to drawings above). Options are 120 & 225
 
Refillable pH or ORP w/ S8 Cap
 
  I-2000  -  DL  -  ZZZ pH electrode
  I-2000  -  DL  -  ZZZ ORP electrode
  * ZZZ = "A" Dimension in millimeters (refer to drawings above). Options are 120, 150, 200 & 250
 
Temperature Compensator Options
 
  0 = None
  B = PT100
  I = 3K Balco
 
Accessories Available
 
  • Wiring Adapters S8, S7 & K9 connectors
  • 316 SS fittings for electrodes
  • Calibration solutions
  • Transmitters
  • Wiring diagrams
 
Note: Spinning Cap design is standard on S8 design with a dimension greater than 120mm.