ISE: Ammonia
A sensor specifically designed to measure Ammonia from 0.01 ppm to 17,000 ppm NH3 (5x10-7 M to 1M) concentrations.
Applications include, but not limited to: High Purity Power Station Water Fish Tanks, Sea Water, Waste Water, Plating Baths, Biological Samples.
|
|
Wiring Adapters
Van London pHoenix Co.'s selection of various wiring adapters and connection gender changing adapters allow you to connect your elecrtode to virtually any meter or controller.
|
|
ISE: Ammonium
A sensor specifically designed to measure 0.1ppm to 18,000 ppm (5x10-6M to 1M) concentrations of NH4.
Applications inclue, but not limited to: Boiler Feed Water, Natural Waters, Fertilizers.
|
|
Steam Sterilizable Carbon Dioxide Electrode
The Van London - pHoenix Co. Steam Sterilizable Carbon Dioxide probe is specifically designed for fermentation applications where it is necessary to subject the electrode to repeated steam sterilizations.
|
|
pH Simulator Model S250
The Model S250 is a precision pH/ORP Simulator for troubleshooting pH & ORP problems.
|
|
ISE: Bromide
A sensor specifically designed to measure 0.4ppm to 79,900 ppm (5x10-6 M to 1M) concentrations of Br-.
Applications include, but not limited to: Water, Wine, Soil and Plant Tissue, Blood Electrolytes/Clinical Analysis.
|
|
ISE:Cadmium
A sensor specifially designed to measure 0.01 ppm to 11,200 ppm (10-7 M to 10-1 M) concentrations of Cd+2.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Calcium
A sensor specifically designed to measure 0.2 ppm to 40,000 ppm (5x10-6 M to 1M) concentrations of Ca+2.
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Blood Elecrtrolytes/Clinical Analysis.
|
|
ISE: Carbon Dioxide
A sensor specifically designed to measure 4.4 pp to 440 ppm (10-4 M to 10-2 M) concentrations of CO2.
Applications include, but not limited to: Soft Drinks, Wine, Fermentation.
|
|
ISE: Chloride
A sensor specifially designed to measure 1.8 ppm to 35,500 ppm (5x10-5 M to 1M) concentrations of Cl-.
Appliations include, but not limited to: River and Tap Water, Plant Tisue, Soils, Boiler Feed Water, Blood Electrolytes/Clinical Analysis, Sweat, Urine, Cement, Plating Baths, Food Samples.
|
|
ISE: Copper
A sensor specifially designed to measure 0.0006 ppm to 6350 ppm (10-8 M to 10-1 M) concentrations of Cu+2.
Applications include, but not limited to: Plating Baths, Water.
|
|
ISE: Cyanide
A sensor specifially designed to measure 0.1 ppm to 260 ppm (5x10-6 M to 10-2 M) concentrations of CN-.
Applications include, but not lmited to: Plating Baths, Waste Water, Plant Tissue.
|
|
ISE: Fluoride
A sensor specifially designed to measure .02 ppm to saturated (10-6 M to saturated) concentrations of F-.
Applications include, but not limited to: Drinking Water, Wastewater and Natural Waters, Air and Stack Gases, Acids, Sea Water, Minerals, Soil, Foods, Biological Fluids, Toothpaste.
|
|
ISE: Fluoroborate
A sensor specifially designed to measure 0.1 ppm to 10,800 ppm (7x10-6 M to 1M) concentrations of BF4-.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Iodide
A sensor specifially designed to measure 0.006 ppm to 127,000 ppm (5x10-8 M to 1M) concentrations of I-.
Applications include, but not limited to: Milk, Feeds andPlants, Pharmaceuticals.
|
|
ISE: Lead
A sensor specifially designed to measure 0.2 ppm to 20,700 ppm (10-6 M to 0.1M) concentrations of Pb+2.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Nitrate
A sensor specifially designed to measure 0.5 ppm to 62,000 ppm (7x10-6 M to 1M) concentraions of NO3-.
Applications include, but not limited to: Surface Waters and Sewage Effluent, Drinking Waters and Soil Extracts, Fertilizers, Soils, Plant Tissue, Meat, Potatoes, Spinach, Beets, Baby Food.
|
|
ISE: Nitrogen Oxide
A sensor specifially designed to measure 0.2 ppm to 220 ppm (5x10-6 M to 5x10-3 M) concentrations of NOx.
Applications include, but not limited to: Air, Stack Gases.
|
|
ISE: Perchlorate
A sensor specifially designed to measure 0.7 ppm to 98,000 ppm (7x10-6 M to 1M) concentrations of ClO4-.
Applications include, but not limited to: Explosives, Solid Propellants.
|
|
ISE: Potassium
A sensor specifially designed to measure 0.04 ppm to 39,000 ppm (10-6 M to 1M) concentrations of K+.
Applications include, but not limited to: Waste Water, River and Tap Waters, Blood Electrolytes/Clinical Analysis, Saliva, Serum, Fertilizer, Soils, Wines.
|
|
ISE: Silver/Sulfide
A sensor specifially designed to measure either 0.01 ppm to 107,900 ppm (10-7 M to 1M) concentrations of Ag+, or
0.003 ppm to 32,100 ppm (10-7 M to 1M) concentratios of Sulfide (S-2).
Applications include, but not limited to: Sewage ffluent, Soils, Sediments (Sulfide), Plating Baths (Silver), Photographic Fixing Solution (Silver).
|
|
ISE: Sodium
A sensor specifially designed to measure 0.02 ppm to 100,000 ppm (10-6 M to 5M) concentrations of Na+.
Applications include, but not limited to: Steam Condensates inPower Plants, Blood Electrolytes/ClinicalAnalysis, Serum, Foods, Wine, Sea Water.
|
|
ISE: Surfactant
A sensor specifially designed to measure 1.0 ppm to 12,000 ppm (10-5 M to 10-2 M) concentrations of surfactants.
Applications include, but not limited to: Detergents, Dishwashing Liquids, Cleaning Supplies, Food Products.
|
|
ISE: Water Hardness
A sensor specifially designed to measure 0.4 ppm to 40,000 ppm (10-5 M to 1M) concentrations of Ca+2 and Mg+2.
Applications include, bt not limited to: Water Softening Systems, Drinking and Mineral Waters, Sea Water.
|
|