ISE: Ammonia
An Ion Selective Electrode sensor specifically designed to measure Ammonia from 0.01 ppm to 17,000 ppm NH3 (5x10-7 M to 1M) concentrations.
Applications include, but not limited to: High Purity Power Station Water, Fish Tanks, Sea Water, Waste Water, Plating Baths, Biological Samples.
|
|
ISE: Ammonium
An Ion Selective Electrode sensor specifically designed to measure 0.1ppm to 18,000 ppm (5x10-6M to 1M) concentrations of NH4.
Applications inclue, but not limited to: Boiler Feed Water, Natural Waters, Fertilizers.
|
|
ISE: Bromide
A Bromide Ion Selective Electrode sensor specifically designed to measure 0.4ppm to 79,900 ppm (5x10-6 M to 1M) concentrations of Bromide.
Applications include, but not limited to: Water, Wine, Soil and Plant Tissue, Blood Electrolytes/Clinical Analysis.
|
|
ISE: Cadmium
A Cadmium Ion Selective Electrode sensor specifically designed to measure 0.01 ppm to 11,200 ppm (10-7 M to 10-1 M) concentrations of Cd+2.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Calcium
A Calcium Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 40,000 ppm (5x10-6 M to 1M) concentrations of Ca+2.
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Blood Elecrtrolytes/Clinical Analysis.
|
|
ISE: Carbon Dioxide
A Carbon Dioxide Ion Selective Electrode sensor specifically designed to measure 4.4 ppm to 440 ppm (10-4 M to 10-2 M) concentrations of CO2.
Applications include, but not limited to: Soft Drinks, Wine, Fermentation.
|
|
ISE: Chloride
A Chloride Ion Selective Electrode sensor specifically designed to measure 1.8 ppm to 35,500 ppm (5x10-5 M to 1M) concentrations of Cl-.
Appliations include, but not limited to: River and Tap Water, Plant Tisue, Soils, Boiler Feed Water, Blood Electrolytes/Clinical Analysis, Sweat, Urine, Cement, Plating Baths, Food Samples.
|
|
ISE: Copper
A Copper (Cupric) Ion Selective Electrode sensor specifically designed to measure 0.0006 ppm to 6350 ppm (10-8 M to 10-1 M) concentrations of Cu+2.
Applications include, but not limited to: Plating Baths, Water.
|
|
ISE: Cyanide
A Cyanide Ion Selective Electrode sensor specifically designed to measure 0.1 ppm to 260 ppm (5x10-6 M to 10-2 M) concentrations of CN-.
Applications include, but not lmited to: Plating Baths, Waste Water, Plant Tissue.
|
|
ISE: Fluoride
A Fluoride Ion Selective Electrode sensor specifically designed to measure .02 ppm to saturated (10-6 M to saturated) concentrations of F-.
Applications include, but not limited to: Drinking Water, Wastewater and Natural Waters, Air and Stack Gases, Acids, Sea Water, Minerals, Soil, Foods, Biological Fluids, Toothpaste.
|
|
ISE: Fluoroborate
A Fluoroborate Ion Selective Electrode sensor specifically designed to measure 0.1 ppm to 10,800 ppm (7x10-6 M to 1M) concentrations of BF4-.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Iodide
An Iodide Ion Selective Electrode sensor specifically designed to measure 0.006 ppm to 127,000 ppm (5x10-8 M to 1M) concentrations of I-.
Applications include, but not limited to: Milk, Feeds andPlants, Pharmaceuticals.
|
|
ISE: Lead
A Lead Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 20,700 ppm (10-6 M to 0.1M) concentrations of Pb+2.
Applications include, but not limited to: Plating Baths.
|
|
ISE: Nitrate
A Nitrate Ion Selective Electrode sensor specifically designed to measure 0.5 ppm to 62,000 ppm (7x10-6 M to 1M) concentrations of NO3-.
Applications include, but not limited to: Surface Waters and Sewage Effluent, Drinking Waters and Soil Extracts, Fertilizers, Soils, Plant Tissue, Meat, Potatoes, Spinach, Beets, Baby Food.
|
|
ISE: Nitrogen Oxide
A Nitrogen Oxide Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 220 ppm (5x10-6 M to 5x10-3 M) concentrations of NOx.
Applications include, but not limited to: Air, Stack Gases.
|
|
ISE: Perchlorate
A Perchlorate Ion Selective Electrode sensor specifically designed to measure 0.7 ppm to 98,000 ppm (7x10-6 M to 1M) concentrations of ClO4-.
Applications include, but not limited to: Explosives, Solid Propellants.
|
|
ISE: Potassium
A Potassium Ion Selective Electrode sensor specifically designed to measure 0.04 ppm to 39,000 ppm (10-6 M to 1M) concentrations of K+.
Applications include, but not limited to: Waste Water, River and Tap Waters, Blood Electrolytes/Clinical Analysis, Saliva, Serum, Fertilizer, Soils, Wines.
|
|
ISE: Silver/Sulfide
A Silver / Sulfide Ion Selective Electrode sensor specifially designed to measure either 0.01 ppm to 107,900 ppm (10-7 M to 1M) concentrations of Silver (Ag+), or 0.003 ppm to 32,100 ppm (10-7 M to 1M) concentrations of Sulfide (S-2).
Applications include, but not limited to: Sewage effluent, Soils, Sediments (Sulfide), Plating Baths (Silver), Photographic Fixing Solution (Silver).
|
|
ISE: Sodium
A Sodium Ion Selective Electrode sensor specifically designed to measure 0.02 ppm to 100,000 ppm (10-6 M to 5M) concentrations of Sodium (Na+).
Applications include, but not limited to: Steam Condensates in Power Plants, Blood Electrolytes/Clinical Analysis, Serum, Foods, Wine, Sea Water.
|
|
ISE: PPB Sodium
A Sodium Ion Selective Electrode sensor specifically designed to measure 0.1 ppb to 10 ppm concentrations of Sodium (Na+). Application include, but not limited to: Power Plants, Boiler Feed Water.
|
|
ISE: Surfactant
A Surfactant Ion Selective Electrode sensor specifically designed to measure 1.0 ppm to 12,000 ppm (10-5 M to 10-2 M) concentrations of surfactants.
Applications include, but not limited to: Detergents, Dishwashing Liquids, Cleaning Supplies, Food Products.
|
|
ISE: Water Hardness
A Water Hardness Ion Selective Electrode sensor specifically designed to measure 0.4 ppm to 40,000 ppm (10-5 M to 1M) concentrations of Water Hardness (Calcium and Magnesium).
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Sea Water.
|
|
Knick Portable Meters
For mobile liquid measurement, Knick has developed the pioneering Portamess® Series for pH, conductivity, and dissolved oxygen. The Portamess® Series combine the accuracy and flexibility of a lab meter with an enclosure design specially developed for field applications.
|
|
Laboratory Electrodes
Van London-pHoenix Co. Laboratory electrodes are designed to be used in a variety of applications. These include water quality, soil pH, non-aqueous media, and education. Both glass and plastic body types are available.
|
|
SZ 283 Potentiostatic electrode
This sensor is designed for the measurement of Free Chlorine, Chlorine dioxide and Dissolved Ozone in water.
Note: This specific model of potentiostatic chlorine sensor is currently not available to OEM customers, and is only available when ordered as a complete package with the B&C CL 7685 Potentiostatic Cl2 Controller and SZ 7231 - SZ 7233 Flow Cells.
|
|
Titration Electrodes
The Van London-pHoenix Co. Titrate electrodes are specially designed for all existing Brinkmann, Metrohm and Schott titration systems. The electrode body is constructed with a glass ground joint that will fit their titration vessels.
|
|
Tuff-Tip Laboratory pH
The Tuff-Tip® is a robust alternative to the conventional laboratory pH electrodes where membrane breakage is a problem.
The Tuff-Tip® is compatible with almost all pH meters.
|
|