| Specifications |
| Compressed air |
oil- and condensate-free |
| Permitted pressure range |
4 … 10 bars |
| Pressure monitoring |
automatic monitoring, message |
| Connection |
1/4" internal thread |
| Rinse water |
filtered 100 μm |
| Permitted pressure range |
2 … 6 bars |
| Temperature range |
5 … 65 °C |
| Pressure monitoring |
automatic monitoring, message |
| Connection |
1/4" internal thread and 3/4" external thread (for coupling) |
| Pump (option) |
cleaning solution |
| Usable bottle volume |
3.5 l |
| Max. lifting height |
10 m |
| Displaced volume |
25 ml / stroke |
| Level monitoring |
continuous, messages |
| Material |
PP, PE, EPDM, (optional FKM), check valves: glass, HC4 |
| Dimensions |
150 mm x 150 mm x 340 mm with 3.5-L bottle |
| Weight |
approx. 1.5 kg (with empty 3.5-L bottle) |
| Supply |
supplied via Protos® PHU module |
| (Ex ia IIC) |
Vi = 8.5 V li = 200 mA Pi = 400 mW 6.8 V (± 10 %) / 15 mA |
| Connection |
terminals, conductor cross section max 2.5 mm‡ (preassembled connecting cable to Protos® 3400) |
| RS 485 |
communication with Protos® PHU module or external host computer (e.g. DCS/PLC) |
| (Ex ia) |
Vi/Vo = 5 V li/lo = 250 mA Ri = 20 ohms |
| Transmission |
1200 bauds / 8 data bits / 1 stop bit / no parity |
| Security |
CRC16 |
| Connection |
terminals, conductor cross section max 2.5 mm2
(preassembled connecting cable to Protos® 3400) max. length 10 m |
| Media connection |
compact multiplug connection for 1 x rinse water, 1 x cleaning liquid, 1 x purge air, 2 integrated check valves for water and cleaning liquid, 2 x compressed air connection for drive, noncontacting electrical limit position control |
| Media adapter |
approx. 2 kg |
| DCS Input M/S |
measuring / Service |
| (Ex ia IIC) |
Vi = 30 V, floating, galvanic isolation up to 60 V |
| Switching voltage |
0 … 2 V AC/DC inactive (measuring)
10 … 30 V AC/DC active (service) |
| Connection |
terminals, conductor cross section max. 2.5 mm2 |
| DCS input A/M |
automatic mechanism blocked |
| (Ex ia IIC) |
Vi = 30 V, floating, galvanic isolation up to 60 V |
| Switching voltage |
0 … 2 V AC/DC inactive (automatic intervals enabled)
10 … 30 V AC/DC active (automatic intervals blocked) |
| Connection |
terminals, conductor cross section max. 2.5 mm2 |
| DCS inputs PRG1 … 3 |
program selection 1 … 8 |
| (Ex ia IIC) |
Vi = 30 V, floating, inter-connected, galvanic isolation up to 60 V |
| Switching voltage |
0 … 2 V AC/DC inactive
10 … 30 V AC/DC active |
| Connection |
terminals, conductor cross section max. 2.5 mm2 |
| DCS outputs ML1 … 3 |
check-back signals: Service, measuring, program
electronic relay contacts, floating, inter-connected |
| (Ex ia IIC) |
Vi = 30 V Ii = 100 mA Pi = 800 mW, galvanic isolation up to 60 V |
| Voltage drop |
< 1.2 V |
| Connection |
terminals, conductor cross section max. 2.5 mm2 |
| Explosion protection |
II 2(1)G Ex ia IIC T4 |
| EMC |
EN 61326
EN 61326/A1 |
| Lightning protection |
EN 61000-4-5, Installation Class 2 |
| Protection against electric shock |
according to EN 61010 |
| Ambient conditions |
5 … 55 °C (Ex: 5 … 50 °C) |
| Ambient temperature |
(different temperature range on request) |
| Transport/Storage temperature |
–20 … +70 °C |
| Relative humidity |
10 … 95 %, not condensing |
| Enclosure |
Uniclean® 900 S Stainless steel A2, polished
Uniclean® 900 C Stainless steel A2, coated, color: pigeon blue |
| Assembly |
wall and pipe mounting (see dimension drawing) |
| Dimensions |
W x H x D approx. 320 mm x 400 mm x 120 mm |
| Ingress protection |
IP 65/NEMA 4X |
| Cable glands |
4 cable glands M 20 x 1.5 |
| Weight |
approx. 9 kg |