Fermprobe® Type Replacements pH/Redox Electrodes TEXT SIZE: A A A    PRINT THIS PAGE   EMAIL THIS PAGE
Fermprobe® Type Replacements pH/Redox Electrodes (BJC F-600, BJC F-610, BJC F-615, BJC F-620, BJC F-635)
 

This series of steam sterilizable and autoclavable pH electrodes has been designed to retro-fit the Broadley James Corp. FERMPROBE® ELECTRODE HOLDER. These electrodes have beeen engineered as improved replacements using the same configuration as the original equipment. These electrodes were designed with a unique solid polymer reference electrolyte and annular ceramic nonfouling reference junction which incorporates a double junction reference cell. These electrodes are special because they can withstand many repeated sterilization cycles with minimal effect to the response or stability. The electrodes are also designed to be reliable and extremely cost efficient.

 

Features Specifications
· Steam Sterilizable · pH Range: 0-13 pH
· Needs NO Pressurization · Temperature Range: -5° to +135°C
· Rugged; Low Maintenance · Pressure: 150 PSIG
· Compatible with ALL pH Instrumentation · Reference: Double Junction

 

ORDERING INFORMATION

pH Electrodes
VLC Part Number Description BJC Part Number BJC Holder
BP600-06B Basic Design (cable) F-600-BXXX-A06BC 320, 330, 340, 350, 355 & 390
BP610-DLG Basic Top, S7 F-610-BXXX-DX None
BP615-06B Tee Pull (Cable) F-615-BXXX-A06BC 320, 330, 340, 350, 355 & 390
BP615-DLG Tee Pull Type, S7 F-615-BXXX-DH 320, 330, 340, 350, 355 & 390
BP620-DLG Bench Top F-620-BXXX-DH None
BP635-DSP 13.5 Threaded, S7 F-635-BXXX-DH 325, 335 & 395
 
ORP (Redox) Electrodes
BP900-06B Basic Design (cable) F-900-BXXX-A06BC 320, 330, 340, 350, 355 & 390
BP910-DLG Bench Top, S7 F-910-BXXX-DX None
BP915-06B Tee Pull (Cable) F-915-BXXX-A06BC 320, 330, 340, 350, 355 & 390
BP915-DLG Tee Pull Type, S7 F-915-BXXX-DH 320, 330, 340, 350, 355 & 390
BP920-DLG Bench Top F-920-BXXX-DH None
BP935-DSP 13.5 Threaded, S7 F-935-BXXX-DH 325, 335 & 395

 

When ordering, determine the length of the electrode (the "B" length) and specify directly in the part number.

 

Part NUmber: BP600-06B-B       †      
† - "B" length in millimeters

 

The following standard "B" lengths are available: 110mm, 120mm, 130mm, 160mm, 210mm, 260mm, 310mm, 360mm and 420mm. Special lengths are available upon request.
Electrode Cables
VL-PC Part Number Description BJC Part Number
9001098-006B BNC plug, 6ft. length, 3mm low-noise coax cable AX-1000-HP-A06BC
9001099-006B BNC plug, 6ft. length, 5mm low-noise coax cable AX-1000-HP-M06BC
9001098-006I DIN 19262 plug, 6ft. length, 3mm low-noise coax cable AX-1000-HP-A06DN
9001099-006I DIN 19262 plug, 6ft. length, 5mm low-noise coax cable AX-1000-HP-M06DN
Fermprobe is a registered trademark of Broadley-James Corporation