Flow Through Dissolved Oxygen Assembly

 

This oxygen system is designed for O2 measurements in a continuous flow-through environment. The Van London - pHoenix Co. flow-through oxygen cell is available in a 6000 µL flow-through cell with ¼” tube connection.

The flow cell is constructed of 316L stainless steel or ultem plastic. The cell and O2 electrode are designed to be steam sterilized in the autoclave with the electrode installed.

Dissolved oxygen electrodes are available in both polarographic and galvanic styles to fill all requirements. The O2 electrode system is compatible with most common O2 amplifiers.

The polarographic dissolved oxygen electrodes are available without temperature compensation. If temperature compensation is needed, a separate temperature compensator is required. Temperature compensation is not normally required when calibration is made at a controlled temperature.

SPECIFICATIONS
 
TypeO25IP18 PolarographicO25NG18 Galvanic
CathodePtPt
AnodeAgAg
Response98% in 60 seconds98% in 90 seconds
Stability*better than 2%better than 2%
Temperature CompensationNoNo
Temperature Range0-60°C0-60°C
Sterilization Temperature130°C130°C
Residual SignalLess than 1 nALess than 0.4 µA
Signal Output**40 nA20 mV
 
* constant temperature** medium saturated with air
 
ELECTRODES
 
PART NUMBERDESCRIPTION
O25IP25-120-10Polarographic electrode (order flow cell separately)
015NG25-120-10Galvanic electrode (order flow cell separately)
8001020Glass flow-through temperature compensator
8001025Glass flow-through temperature compensator PT100 Ohm RTD
 
FLOW-THROUGH CELLS
 
PART NUMBERDESCRIPTION
1051001316L Stainless Steel flow cell, 6000 µL (other sizes available upon special order)
1001010Ultem flow cell, 6000 µL (other sizes available upon special order)
 
ACCESSORIES
 
PART NUMBERDESCRIPTION
M0500P1-K5Membrane service kit for polarographic electrodes, includes three membrane cartridges, filling solution, and O-rings.
M0500NG1-K1Membrane service kit for galvanic electrodes, includes three membrane cartridges, filling solution, and O-rings.
M0500P2-M6One replacement polarographic membrane cartridge and O-rings
M050NG1-M1One replacement galvanic membrane cartridge and O-rings
R001068Filling solution - 125 mL for polarographic electrodes
R001069Filling solution - 125 mL for galvanic electrodes
 
CABLES
 
PART NUMBERDESCRIPTION
9001091-010BBNC Connector
9001091-010IDIN Connector
9001091-010DDual Pin Connector
9001091-010UBanana Pulgs
9001091-010TNo Connector
9001091-010CCCuston cable with choice of plug, lemo connector. Specify aize and pin number.
 

 