461 Differential pH and 3/4 Inch MPT Conventional pH V-4000
  • Improved Life and Performance
    Van London-Phoenix Co. electrode designs have been field proven in a variety of harsh applications and when manufactured with our Solid Polymer Reference™ fill the life of the electrode is prolonged and the overall performance of the electrode is enhanced.
     
  • Custom Styles
    Housings can be machined from numerous materials with several electrode guard designs and various insertion depths. Custom electrode designs can maximize sensor in harsh environments.
  • Quick Order Turn-around
    An inventory stocking arrangment reduces lead times from weeks to days. Housed electrodes generally consist of two parts: a 12mm glass-bodied electrode and a housing machined to accept that electrode. Minimal factory assembly is required before shipment to the customer site.
     
  • Easy, Low Cost Replacement
    Direct replacements are dimensionally matched to existing equipment so that no expensive retrofit changes are necessary. Simple, quick removal of the replacement element for Van London-Phoenix Co. standardization is all that is required.
 
ELECTRODE SELECTION
 
Measurement Types:  GXV - Multi-purpose pH glass formulation (0-14.00 pH)
Platinum Band - For ORP measuremnt (Gold optional)
Antimony - For pH measurements in Hydrofluoric Acid appilcations (2.00-7.00 pH) (0-80°C)
 
Reference Types:  SPR™ - Double junction, SOLID POLYMER REFERENCE (0-130°C)
Tuff-Tip™ - New design incorporating larger reference junction surface area & electrode guard.
LCJ - Dramatically increases the reference junction surface area. Standard material is ceramic, but porous Teflon and porous Kynar are available.

 
-  Call with Great Lakes part numbers for cross-reference to Van London-Phoenix Co. equivalents.
-  To build your own Part Numbers, first determine the electrode replacement, style required, and then replace the X's, Z's & Q's with selections listed in the drop down menu.
 Electrode Selection
461 - ZX  : Differential pH/5 Wire Sensor/1" MPT Kynar™ housing
V-900 - ZX10 H : Conventional pH/1" MPT Kynar™ housing
 ||
 |Measuring Electrode Options
 |0 ORP
 |V pH
 |
ACCESSORIES:
 
3600105Reducer, Kynar™ 1½" x 1"
9210082Differential Refill Solution
1602100461 Reference Junction
 Temperature Compensation (z)
 B PT100
 1 3K Balco
 7 NTC 300
 
458P -Z - XX - QQ Preamp Assembly
 |||
 ||Connector Type
 ||SL Spade Lugs
 ||H Hanked (Tinned)
 ||
 |Lead Length
 |Specify lead length in even feet
 |
 Preamp Section
 0 No Preamp
 5 (Conventional)
 G (Differential / 5 Wire)
 ELECTRODE SOLUTIONS
 
  92100384.00pH, 7.00pH and Deionized Water rinse (1 pint each)
  92100374.00pH, 7.00pH and 10.00pH (1 pint each)
  92100397.00pH, 10.00pH and Deionized Water rinse (1 pint each)
  9210079Anti-fouling solution to reduce electrode-coating problems
  9210008-125Electrode storage solution KCl/4.00 pH buffer (125 ml)
 
 Eutech Instruments for pH, ORP, Conductivity, Resistivity & TDS:
 