Glass Body Dissolved Oxygen Electrodes TEXT SIZE: A A A    PRINT THIS PAGE   EMAIL THIS PAGE

The glass body Dissolved Oxygen electrodes are available for laboratory fermentation, where sterilization takes place in a separate autoclave. The disposable Van London Co. Dissolved Oxygen Electrodes are compatible with most common oxygen amplifiers.

Glass Body Dissolved Oxygen Electrodes

This series of steam sterilizable, Dissolved Oxygen electrodes are designed for economical use. They are constructed very similarly to the standard pH electrode, and have a 10 and 12mm body, and can be ordered with the desired “H” length. The “H” length is determined by the insertion depth on the under side of the fermentor headplate to the tip of the probe. Glass disposable Dissolved Oxygen electrodes are available in both polarographic and galvanic styles to fit all requirements.

GALVANIC D.O. PRODUCT WARNINGS

P65Warning WARNING: Cancer & Reproductive Harm - www.P65Warnings.ca.gov

 

The glass body Dissolved Oxygen probes are available for laboratory fermentation, where sterilization takes place in a separate autoclave. The disposable Van London Co. Dissolved Oxygen Electrodes are compatible with most common oxygen amplifiers. Glass body Dissolved Oxygen electrodes are non-temperature compensated and are required to be kept at a constant temperature. Calibration must be made at the same temperature as the controlled fermentation. The electrodes feature external filling tubes. Electrolyte can be added during use without removing the electrode from the vessel. The electrode membranes can be replaced very easily. However, some skill is involved in replacing them.

 
Type 027IP15
Polarographic
027BG15
Galvanic
027NG15
Galvanic
CATHODE Pt Ag Ag
ANODE Ag/AgCl Pb Pb
RESPONSE 98% in 60 seconds 98% in 90 seconds 98% in 90 seconds
STABILITY* Better than 2% Better than 2% Better than 2%
TEMPERATURE COMPENSATION NO NO NO
TEMPERATURE RANGE 0-60°C 0-60°C 0-60°C
STERILIZATION TEMPERATURE 130°C 130°C 130°C
RESIDUAL SIGNAL Less than 1 nA 0.5 - 1 mV Less than 0.4 µA
OUTPUT** 50 nA 40 mV ± 5 mV 10-15 µA
 
* = Constant Temperature ** = Medium Saturated With Air
 
ORDERING INFORMATION
 
PART NO. "H" LENGTH BODY DIAMETER TYPE
027IP15 "H"-DL 12 mm Polarographic
*027BG15 "H"-DL 12 mm Galvanic
027IP15 "H"-DL 10 mm Galvanic
 
* Must be used with 9001094-010U.
 
MEMBRANE SERVICE KITS AND FILLING SOLUTION
 
PART NUMBER DESCRIPTION
M0500T1-K5 Membrane Service Kit K-5 for both Polarographic and Galvanic O2 electrodes. Consists of 10 membranes 1 mil thick and 10 silicone bands
M0500T2-K5 Membrane Service Kit K-5 for both Polarographic and Galvanic O2 electrodes. Consists of 10 membranes 2 mil thick and 10 silicone bands
R001068 Polarographic O2 electrode filling solution, 125 mL.
R001069 Galvanic O2 electrode filling solution, 125 mL.
 
CABLES
For non-temperature compensated O2 electrodes, used with Polarographic and Galvanic O2 electrodes. Standard 3 meter lead.
 
PART NUMBER DESCRIPTION
9001091-010B BNC Connector
9001091-010I DIN Connector
9001091-010D Dual Pin Connector
9001091-010U Banana Plugs
9001091-010T No Connector
9001091-010CC Custom cable or for use when customer supplies connector
9001093-010D Pin Connector. Cable features a load resistor for direct connection to a recorder with mV output. (Approximately 40 mV saturated air/water)