ABB (TBI) CONTROLS REPLACEMENTS |
 6103 GLENMONT · HOUSTON, TEXAS · 77081
800/522-7920 · FAX: 713/772-4671 · 713/772-6641
www.VL-PC.com |
 |
- Improved Life and Performance
Van London-Phoenix Co. electrode designs have been field proven in a variety of
harsh applications. In most cases, direct replacements will outperform original equipment specifications.
|
- Easy, Low Cost Replacement
Direct replacements are dimensionally matched to existing equipment so that expensive
retrofit changes are not necessary. For standardization, simply remove the original element and replace with a Van London-Phoenix Co. equivalent.
|
- Quick Order Turn-around
Housed electrodes consist of two parts: a housing and an electrode. Housings are machined to accept
any number of stocked 12mm electrodes and require minimal factory assembly prior to shipment.
|
- Custom Styles
Housings can be machined from numerous materials with several electrode guard designs and various
insertion depths. Custom electrode designs can maximize sensor life in harsh environments.
|
|
| ELECTRODE SELECTION |
| |
| Measuring Types: |
GXV - Multi-purpose pH glass formulation (0-14.00 pH)
Platinum Band - For ORP measurement (0-130°C)
Antimony - For pH measurement in HF applications, 2-7 pH (0-80°C) |
| Reference Types: |
SPR™ - Double junction, solid polymer reference (0-130°C)
Tuff-Tip™ - New design incorporating a larger reference junction, surface area & electrode guard.
LCJ - Dramatically increases the reference junction surface area. Standard material is ceramic, but porous Teflon® and porous
Kynar® are available. |
|
| |
| SPECIFICATIONS |
| |
| Housing Materials: | Kynar® and Viton® |
| Pressure Ratings: | TB551 - 100 psi @ 140°C; TB556 - 100 psi @ 80°C
TB557 - 100 psi @ 80°C; TB564 - 300 psi @ 140°C TB567 - 250 psi @ 100°C |
|
| |
| ORDERING INFORMATION |
- Call with TBI/ABB part numbers for quick cross-referencing to Van London-Phoenix Co. equivalents.
- To build your own part number, first determine the electrode style required and then replace X's, Z's & Q's with selections listed in the drop-down
menus:
|
|
| A | - | 2 | 0 |
0 | Z | - | XX |
BH | : TBI/Bailey TB551 Replacement |
| V | - | 4 | 0 |
0 | Z | - | XX |
BH | : TBI/Bailey TB556 Replacement |
| A | - | 3 | 0 |
0 | Z | - | XX |
BH | : TBI/Bailey TB557 Replacement |
| A | - | 1 | 0 |
0 | Z | - | XX |
BH | : TBI/Bailey TB567 Replacement |
| *Note: Platinum Band & Antimony Billet |
| | | | | |
| | | | Lead Length |
| | | | Specify lead length in even feet |
| | | |
| | Automatic Temperature Compensator (ATC) |
| | 1 3,000 ohms @ 25°C |
| | B 100 ohms @ 0°C |
| |
|
| |
| SPARE PARTS |
| |
| |
5205-118 | Twist-Lock Adapter (316SS) for 551 |
| |
5205-117 | Twist-Lock Adapter (epoxy) for 551 |
| |
3500720 | Titanium Sheath, 16" for 557 |
| |
1600720 | Rear Housing for 557 |
| |
4TB5101-0166 | High Pressure Sheath for 567 |
| |
4TB4953-0060 | Gland, hand tightened (316SS) for 557 |
|
| |
Additional electrode styles, materials and Wiring Adapters are available. Consult the factory for options. |
| |
| ELECTRODE SOLUTIONS |
| |
| |
9210038 | 4.00pH, 7.00pH and Deionized Water rinse (1 pint each) |
| |
9210037 | 4.00pH, 7.00pH and 10.00pH (1 pint each) |
| |
9210039 | 7.00pH and 10.00pH and Deionized Water rinse (1 pint each) |
| |
9210079 | Anti-fouling solution to reduce electrode-coating problems |
| |
9210008-125 | Electrode storage solution KCl/4.00 pH buffer (125 ml) |
|
| |
|
FOR ADDITIONAL PRODUCT INFORMATION,
CALL 713/772-6641 OR 800/522-7920
E-mail: sales@VL-PC.com
www.VL-PC.com
|
| Kynar is a trademark of Pennwalt Corporation. |
Viton, Teflon, and Kalrez are trademarks of E.I. Dupont de Nemours & Co. |
| SPR is a trademark of Van London-Phoenix Co. |
|
©2008 Van London-pHoenix Company